Sharepoint Servers which run on Windows Server 2008 are not getting discovered at all

Hi all! The Configuration Task from the SCOM Console executed successfully without the slightest error? You checked also the configuration from the SharepointMP.config and it matched the run as account (if there is none configured SCOM will run it with the default action account) + the all SharePoint Servers are configured correctly. There is no…

1

SChannel Errors on SCOM Agent

Hi again!   If you`re setting up a new agent/ Gateway installation which cannot communicate with the Management Server it`s always a good idea to also check the System Event Log and check for SChannel errors like:   Event ID: 36874- TLS 1.2 connection request was received from a remote client application, but none of…

12

edb.log – The process cannot access the file because it is being used by another process.

If you receive following errors in the Operations Manager Event Log:   Event ID 455  Description: HealthService (36900) Health Service Store: Error -1032 (0xfffffbf8) occurred while opening logfile C:\Program Files\System Center Operations Manager\Agent\Health Service State\Health Service Store\edb.log. Event ID 489 Description: HealthService (36900) Health Service Store: An attempt to open the file "C:\Program Files\System Center…

1

Web Application Availability Monitor not monitored

Here are some steps to troubleshoot when the Web Application Availability Monitor is not instantiated in the SCOM console (the green circle is not filled ). 1. Check the URL designed to be monitored from the server configured in the monitor. 2. Create a new monitor for a web url that works, for example www.bing.com .. if…

1

Visual Studio Authoring Extension overview

This is a tool which I find purely awesome… The System Center 2012 Visual Studio Authoring Extensions—VSAE— which is an add-in for Visual Studio 2012/2013 Professional and Ultimate which provides a couple of tools to better support Management Pack Authoring. In 2007, there was also the Authoring Console, but this has degraded .. and the…

1

ACS forwarders disconnecting

Hi again! Basically ACS is fairly easy to set up, however after getting it to run, it`s not over. It is very important to check for the status of the event collection to prevent performance degradation. By architecture, if the collector queue (default at 90%) gets full, it will begin to disconnect forwarders in order…

0

Discovery for XenApp Server (Linux) is not successful

When running discovery for xenapp servers following error would be displayed in the discovery wizard from the SCOM Console (2012 SP1 CU3): Unexpected DiscoveryResult.ErrorData type. Please file bug report. ErrorData: Microsoft.SystemCenter.CrossPlatform.ClientLibrary.MPAbstractions.WSManUnknownErrorException The WinRM client received an HTTP status code of 403 from the remote WS-Management service. at System.Activities.WorkflowApplication.Invoke(Activity activity, IDictionary`2 inputs, WorkflowInstanceExtensionManager extensions, TimeSpan timeout)…

2

Cannot install SCOM 2012 SP1 on a SQL Always ON instance

So, you`re trying to install SCOM 2012 Sp1 with a SQL Always On Group.. you get to the configure the operational database step of the setup and get following error: Setup is unable to create database on SQL Server instance "your SQL Always On Instance" Please make sure that the current user has permissions to create…

0