Sometimes you may be unable to upgrade Virtual PC Integration Components  with error “Setup Interrupted”.


In most of cases, the Kernel mode driver framework files wdf01000.sys and wdfldr.sys may be the cause of this issue from the following workaround:

1. Unistall Virtual PC Components

2. Remove the device that is unrecogonized from the device manager

3. Rename the following 2 files

C:WINDOWSsystem32DRIVERSwdf01000.sys and


4. Restart the system

5. Install the Integration components

6. When the hardware wizard comes, select to manully to install, enter the path in the first option – C:Program FilesVirtual PC Integration Components and click next. it should recogonize the unrecogonized device

7. Restart and enable the Integration features